Безопасность применения препаратов крови по данным пострегистрационного мониторинга
Ирина Илларионовна Снегирева, Борис Константинович Романов, Н А Озерецковский · Успехи современного естествознания · 2015
The article presents results of analysis of adverse reactions in patients after administration of human blood products (normal and specific immunoglobulins, albumin), animal blood products (antitoxin sera, specific immunoglobulins), and recombinant blood products, that are registered in the international and two national databases. Whereas in the international database blood products have never been among top 20 drugs accounting for the largest number of reports on adverse reactions over 46 years of monitoring, in the Russian Federation severe allergic reactions caused by administration of heterologous serum products (antitetanica horse serum, antirabies immunoglobulin from horse blood serum) accounted for 5,6-11 % of all annual reports of adverse reactions caused by administration of immunobiological products, including vaccines of the National immunizations schedule. Main clinical signs of serious adverse reactions to blood products are immediate-type (type 1) allergic reactions that are registered after administration of both homoand heterologous products and type 3 reactions (serum disease) that arise after administration of heterologous sera. Prevention of serum disease development is only possible by replacement of animal serum-derived drugs by a corresponding human blood serum-derived products.
Cited by 0 works.