Биосенсорная тест-система на основе иммобилизованного фермента ацетилхолинэстеразы для определения карбофоса
А. М. Филиппова, Vorob'eva Ov, С. С. Аванесян · Современные проблемы науки и образования · 2012
The way of reception of a biosensor test system on the basis of natural polymers with immobilized enzymeacetyl-cholinesterase is developed. There are presented comparative characteristics of the specific activity of the immo-bilized enzyme and that of the soluble one, the data showing the change of the specific activity of the immobilized enzyme with and without its inhibitor karbofos.Studies of the factors which influence the sensitivity of the enzyme and the reduction of its specific activity while being immobilized are carried out. It is shown that the specific activity of the immobilized enzyme is reduced with the inhibitor present. The developed biosensor test-system is evaluated on model systems. The received biosensor test-system on the basis of the immobilized enzyme acetyl-cholinesterase is easy in use and non-toxic.The test system determines the karbofos concentrationsin the range from 0.76×10-3mmolto 45×10-3mmol.
Cited by 0 works.