유도 전동기의 토크신호를 이용한 베어링 고장진단 연구
홍영희, 선현규, 박진엽 · 대한전기학회 학술대회 논문집 · 2009
The motors faults including mechanical rotor imbalances, broken rotor bar, bearing failure and eccentricities problems are reflected in electric, electromagnetic and mechanical quantities. This paper presents a study and the practical implementation of an induction motor for reactor containment fan cooler in nuclear power plant with Electric Signature Analysis(ESA). The results obtained present a good degree of reliability hence; the ESA predictive maintenance tools enable a pro-active evaluation of induction motors performance prior to failure.