공동주택에서의 활동별 수증기 발생량 측정 및 확산 특성 분석
임영훈, 송두삼 · 대한설비공학회 2015년도 하계학술발표대회 · 2015
Recently, the air change rate in apartment building is decreased due to the enhanced air-tightness and insulation level. Lack of air change rate makes hard to eliminate pollutants including water vapor. This problem can cause condensation or mold in apartment building. Condensation in multi-residential buildings is caused by the low insulation level of the wall and excessive generation of indoor water vapor. The government enhanced the code for insulation level to raise the surface temperature of the wall for prohibiting the condensation in multi-residential buildings. However the condensation still has been reported, and it is because of the excessive vapor generation in buildings. The purpose of this study is to develop the indoor humidity control system to prohibit the condensation in residential buildings. To achieve this purpose, the behaviors of water vapor generation rate by activities and its diffusion characteristics in buildings should be analyzed. In this paper, the water vapor generation rates by activities in multi-residential building were measured, and its diffusion characteristics were analyzed by field measurement.
Cited by 0 works.