분극저항 측정 방법을 이용한 콘크리트 중의 철근부식 전류밀도 산정을 위한 스테른-기어리 상수 B(㎷)값 분포에 관한 고찰

김제남, 지남용 · 한국콘크리트학회 2007년도 가을 학술발표회 논문집 · 2007

Using Stern-Geary equation (Icorr=B/Rp), a value of Icorr was calculated from LRP using a range of B values. For the steel in the active corrosion state, difference in B value results significant changes in calculated Icorr values and influences estimating the decrease in rebar cross-section. Therefore, the more accurate value of B is need for measuring corrosion rate. In this study, the distribution of B values in concrete was investigated by analyzing measured data on concrete specimen. The results indicate that using B=26㎷ may yield an error higher than two orders of magnitude and the difference in concrete cover inflences the B constant value.

Cited by 0 works.