최대산소섭취량 측정 시 측정간격에 따른 정체현상의 변화와 종료기준의 적용
윤병곤, 곽이섭 · 2007
The purpose of this study was to elucidate incidence of VO₂ plateau by comparing data derived from different time averaging intervals during incremental cycling exercise to VO₂max. Seventeen subjects (age: 23.5±3.3 years and VO₂max: 3.65±0.73 L/min, respectively) completed VO₂max tests on cycle ergometer which breath by breath gas exchange data were obtained. These data were time-averaged into 11-breath, 15, 30 and 60 s sampling intervals. The incidence of plateau were 100, 35, 24 and 6% for the 11 breath, 15 s, 30 s and 60 s averaging, respectively. No correlation was between △VO₂ at VO₂max and VO₂max (r=-0.008). 53% (maximal HR within 10 b/min) and 100% (RER≥1.15) of subjects met the criteria for attainment of VO₂max. This data indicate that shorter sampling intervals (11 breath) is the most suitable for detection of the VO₂ plateau and RER can be used for the criteria for attainment of VO₂max but not maximal HR. Also, the incidence of a plateau is not related to training status or physical fitness of subjects.