적외선열화상카메라를 이용한 건식벽체에 부착된 타일에 대한 시공상태 점검기준
한윤정, 마승재, 최성민 et al. · 한국건축시공학회 학술.기술논문발표회 논문집 · 2015
In this study, it is contemporaneously understood that tile attachment on CRC board do not have a regulated standard on quality control and construction. Furthermore, there is also a definite lack of standardization on nondestructive inspection of tiles. This thesis investigates a diagnosis method of spot bonding tile attachment using infrared thermal camera as a way to propose a systematic nondestructive inspection method after tile construction.