토크-전단형 고력볼트의 체결하중 변화에 따른 장기축력이완 평가
이현주, 나환선, 김강식 · 한국강구조학회 학술발표대회 논문집 · 2011
The slip load occurred to slip critical connection is determined to multiply slip coefficient by clamping force and it is essential to induce the proper tension force to high strength bolts in order to assure the required design slip resistance. In domestic construction sites, the service load of high strength bolts is applied by torque control method. So, the deviation of the service load is critical considerably how well the quality control of torque coefficient was done. In this study, slip resistance subjected to the variation of clamping force ranging up from 60% to 120% was evaluated. Additionally, the relaxation test for 1,000 hours was conducted. The candidates were torque-shear bolt. The test result exhibited that slip resistance loads were reduced similarly to the line of reduction of service load. The relaxation rate was the lowest 8.6% at clamping force 120% and the highest 10.9% at clamping force 60%.
Cited by 0 works.