유체의 유입위치와 회전길이에 따른 이중관 열교환기의 유동특성

차동안, 이승하, 권오경 et al. · 대한기계학회 춘추학술대회 · 2012

The length and position of the inlet port on the double tube heat exchanger is analyzed by CFX ver.11 for studying the characteristic of its flow uniformity. When the boundary conditions of the inlet temperature and mass flow rate were each 20 ℃ and 10 ~ 50 ㎏/min, 3 models that are based on the distance between the inlet port and the center of the heat exchanger(0, 5.025, 10.05 ㎜) were analyzed to find the uniformity of the flow rate. Based on the flow rate, 4 rotating lengths (23.723, 33.890, 44.057, 57.274 ㎜) were used to study the flow distribution according to Reynolds Number. The results show that, when the distance from the inlet to the position of the center of the heat exchanger is 10.05 ㎜ and the rotating length is 57.274 ㎜, the flow uniformity is the most unified.

Cited by 0 works.