철골모멘트골조의 내진성능 향상을 위한 기둥소성힌지 설계조건 검토
최세운, 박효선 · 대한건축학회 학술발표대회 논문집 - 구조계 · 2011
The purpose of the column-to-beam strength ratio criteria is to reduce the seismic damage of buildings through inducing beam-hinges collapse mechanism. The current seismic design codes using the column-to-beam strength ratio criteria apply this condition to all joints excluding the joints of top story. The purpose of this study is to confirm wheather preventing the plastic hinges on all column end part is neccesary. Various non-dominated solutions, which are minimized the structural weight and maximized the dissipated energy, are obtained using NSGA-II. They are checked wheather the plastic hinges are developed at the end-parts of columns. The 3-story steel moment frame is used as an example.
Cited by 0 works.