부분 예혼합화염에서 연소실 압력변동이 연소특성과 반응대 두께에 미치는 영향

손제하, 김종률, 나종문 et al. · KOSCO SYMPOSIUM 논문집 · 2010

The influence of changing combustor pressure(-30~30㎪) on combustion characteristics and local reaction intensity was investigated by measurements of reaction zone thickness in partially premixed flames. EINOx and temperature distributions were decreased with decreasing combustor pressure. For rich conditions, a combustor pressure lower than the atmospheric pressure enhanced the combustion reaction by increasing the diffusion velocity of unburned mixture. Flame structure was also affected changing pressure. In order to observe reaction zone thickness, CH * chmiluminescence intensity was measured because CH * is dominant radical among the chemical species. The reaction zone thickness was defined by FWHM of CH * intensity distribution. The reaction zone thickness was increased with decreasing combustor pressure and increasing equivalence ratio. In case of Φ?1 condition, a difference of reaction zone thickness was decreased with increasing combustor pressure. For rich conditions, we could observe contrary tendency, because enhanced diffusion velocity of unburned mixture was affected reaction zone thickness.

Cited by 0 works.

Authors