육상용 2㎿급 직접구동형 풍력발전기의 성능 민감도 분석
노주현, 윤광용, 이권희 · 대한기계학회 춘추학술대회 · 2010
Load calculations for wind turbine system design are important to determine the efficiency of wind turbine system. Although mean wind speed or turbulence intensity satisfy the designed values based on the Regulations, the designed values can be different to the values on real wind conditions. To know the characteristics in sharply turned, the performance analysis and sensitivity calculations were carried out by applying the ranges of 7~10㎧ mean wind speed and 14~20% turbulence intensity about 2㎿ direct drive wind turbine of IEC class Ⅱ designed for onshore. The sensibility of Hyundai Rotem wind turbine changes rapidly in region Ⅱ on power curve diagram through a torque control to a pitch control. This results could be applied to the optimal control logic design by the load calculation results.
Cited by 0 works.