Роль электрокардиографических параметров при прогнозировании эффективности сердечной ресинхронизирующей терапии

О. Л. Бокерия, Калысов Курбанбек Абдишукурович · Анналы аритмологии · 2012

QRS до и после проведения СРТ, морфологии QRS (наличия БЛНПГ) и локализации ЛЖ-электрода.Over the past ten years, it was shown that cardiac resynchronization therapy (CRT) leads to improvement of cardiac pumping ability and reduce of symptoms in patients with chronic heart insufficiency (CHI), reverse remodeling of left ventricle (LV), improvement of the quality of life and even to survival increase. The recent meta-analysis that combined more than 3000 patients with resynchronized devices from 6 large multinational randomized trials demonstrated that CRT led to reduce mortality from all the reasons by 29% and to reduce hospital admissions from CHI progression by 37%. However, at the same studies, it was shown that from 30% to 50% of all the patients who were not included in inclusion common criteria of randomized controlled studies had no response to CRT in the proper way. The main reasons of such number of non-responders to CRT are the following: bad selection of patients, inadequate localization of the left ventricle electrode and bad selection of parameter programming. It is shown that the number of responders to CRT is increasing if the end of the electrode appropriates to the myocardial area with late activation. Furthermore, functional class improvement in heart failure and reverse remodeling of LV are in direct relation depending on the degree of concordance between the end of the left ventricular electrode and the area with late activation. After the result analysis of the number of studies, there is some correlation between the change of the wide of QRS complex before and after resynchronized device implantation and functional response to resynchronized therapy. Thus the shorter is the width of QRS complex with CRT the more pronounced is CRT response. Optimization of the patients management after implantation of the device and programming improvement of the resynchronized device as well as the better selection of patients can potentially decrease the number of patients who did not respond to CRT. Prognostic criteria of inefficient CRT according to some investigations are: elderly age, male sex, ischemic heart disease, atrial fibrillation, left bundle-branch block (LBBB) absence and QRS complex duration less than 150 ms. However it is not clear which of the above mentioned factors is the main predictor of bed response to CRT. In this review the authors summarized and analysed the results of the investigations dedicated to CRT efficiency prediction depending on the QRS complex width before and after CRT, QRS morphology (LBBB availability) and LV electrode location.

Cited by 0 works.

Authors