Компьютерная томография в диагностике кистозных аденоматоидных мальформаций легких у новорожденных

Баженова Юлия Викторовна, Дрантусова Наталья Сергеевна, Краснов Павел Анатольевич et al. · Сибирский медицинский журнал (Иркутск) · 2015

Cystic adenomatoid malformation of the lung (CAM) is a rare congenital pathology of terminal bronchioles. The goal of this work was the assessment of capability for multidetector computed tomography (MDCT) in the diagnosis of cystic adenomatoid malformation at newborns. In work the results of inspection are plugged 10 patients being on treatment in a regional perinatal center in the period from 2010 to 2014 for the estimation ofCAMused classification of J.T. Stoker (1977г). The description of computer-tomography symptoms of congenital cystic adenomatoid malformation. That’s why, MDCT is a method to noninvasively and precisely diagnose of changes of lungs at newborns, to reduce such serious disease, asCAM, to go into detail character and volume.

Cited by 0 works. doi:10.1234/xxxx-xxxx-2015-2-132-135