김정배, 주문창, 윤응상 et al. · 대한기계학회 춘추학술대회 · 2006

Parametric experiments for evaluating the performance of fresh water generator applied plate type heat exchanger were performed in this study. The test facility for the performance test were designed and manufactured. The maximum fresh water yield of the fresh water generator applied in this study was designed as 1.5 Ton/day. The parameters relating with the performance of fresh water generator are known as sea water inlet temperature, hot water inlet temperature, and hot water flow rate. The test ranges for each parameters were 10, 20, and 30℃ for sea water inlet temperature, 65, 75, and 85℃ for hot water inlet temperature, 2.0, 2.5, and 3.0㎥/hr for hot water inlet volume flow rate, respectively. And the experiments to reveal the accuracy of experimental apparatus and to show the repeatability and reproducibility were also performed. The quantitative analysis for the heat transfer mechanism and mass balance under physically possible assumptions is also conducted with simple thermodynamic equations. The experimental and estimated quantities were compared. Through the experiments and simple analysis, this study showed detail operation characteristics of fresh water generator with plate type heat exchanger.