Комбинированный метод определения оптической силы интраокулярных линз после кератотомии

Богуш Илья Васильевич · Сибирский научный медицинский журнал · 2009

The study has bee performed to analyze the accuracy of a method of calculating intraocular lens (IOL) power after radial keratotomy (RK) and compare it with other methods when a pre‑refractive history is unavailable. The modified SRK/T method was applied in cataract phakoemulsification for IOL calculation after RK in 33 cases. Pre‑refractive K‑values were obtained by approach of corneal topography recreation, post‑refractive K‑values were obtained from center 3.0 mm diameter of keratotopography map. Accuracy (ΔIOL) was calculated as difference of theoretic IOL power (IOLemme) and calculated IOL power by different methods (IOL1‑5). Mean refractive errors ± SD of methods were obtained: suggested 0.64 ± 0.38 D, Malony‑Koch method 1.56 ± 1.66 D, Rosa method 2.27 ± 1.30 D, Shammas method 1.26 ± 1.03 D, SRK/T formula 2.34 ± 1.68 D (р