서지 제어를 위한 입구 안내익 터보 압축기 모델
정진희, 한재영, 유상석 et al. · 대한기계학회 춘추학술대회 · 2013
Turbo compressors are typically used to supply pressurized air for many industrial plants. Since surge is critically affecting the performance and durability of turbo compressor, it should be avoided for secure operation. As turbo compressor is required to be coped with a broad range of operations, it is necessary to understand the operating locus of the compressor. In this study, the Thermolib ® of Simulink ® library is used to provide the basic components of the model for developing large-capacity turbo compressor model. The compressor was modeled to be three stages for simulating a high discharge pressure. A large capacity compressor employs inlet guide vane to control the performance of compressor. In this study, the inlet guide vane is also modeled under Simulink ® environment so that the performance is properly controlled for surge avoidance. Finally, the simulation model is used to understand the surge margin and surge avoidance strategy with inlet guide vane.
Cited by 0 works.