정밀통신 보안 시설물 하부 통과구간 발파진동 저감사례연구

이상헌, 이진무, 이효 et al. · 한국암반공학회 학술대회 및 세미나 자료집 · 2009

Very sensitive precision communication security facilities(allowable vibration level : 0.05cm/s) are located over the Haeundae tunnel(which is located at East Sea Nambu(Busan~Ulsan) double track line, the third section of construction work). At the First design, We applied mechanical rock crush method to observe the allowable vibration level. But after analyzing the construction efficiency and term of works, we've found some problems. So we reflect precision vibration control blasting pattern which is created by pre-large horizontal hole and electronic delay detonator System. As a result of using precision vibration control blasting pattern, measured vibration level on the lower part of facility of super-approach section is 0.035~0.047cm/s, which satisfied allowable vibration level. As the 2-3m excavation per day by mean advance efficiency of 90~95% has been possible, we are expecting that we can ensure the safety for the precision communication security facilities and reduce excavation term.