대류방식을 이용한 열유속센서의 검정에 관한 연구
양훈철, 송철화, 김무환 · 대한기계학회 춘추학술대회 · 2004
The objective of this work is to propose calibration facility in which a thin film type heat flux sensor can be calibrated under convective flow condition by using a small wind tunnel with the constant temperature plate condition. A small wind tunnel has been built to produce a boundary layer shear flow above a constant temperature copper plate. 12-independent copper blocks, thin film heaters, insulators and temperature controllers were used to keep the temperature of flat plate constant at a specified temperature. Three commercial thin film-type heat flux sensors were tested. Convective calibrations of these gages were performed over the available heat flux range of 1.4~2.5 ㎾/㎡. The uncertainty in the heat flux measurements in the convective-type heat flux calibration facility was ±2.07%. Non-dimensional sensitivity is proposed to compare the sensitivity calibrated by manufacturer and that of experiment conducted in this study.
Cited by 0 works.