In this study, the performance prediction and experiment of loop heat pipe(LHP) were performed. A LHP has a wick only in its evaporator for the circulation of working fluid, and utilizes a porous wick structure of which pore size is very small to obtain a large capillary force. The diverse parameters on the operation of loop heat pipe (LHP), such as particle diameter of sintered porous wick, wick porosity, height between evaporator and condenser, and heating capacity affect the performance of LHP. For the LHP that the working fluid is water and the materials of sintered porous wick are stainless and ceramic particle, temperature-pressure distribution, the pressure drop in vapor line and liquid line, and saturation temperature in evaporator and condenser were analyzed by the theoretical design method of LHP and experiment was performed.