이젝터를 이용한 고공환경 시험 리그 구축 및 성능 시험

유이상, 김태완, 우희찬 et al. · 한국추진공학회 학술대회논문집 · 2013

Performance test and construction of a high altitude simulating system which consisted of a thermal vacuum chamber and an ejector were conducted. A high altitude pressure condition was simulated by the ejector with secondary flow rate to simulate a combustion gas. In addition, the thermal vacuum chamber was designed with a heat exchanger to simulate low temperature of a high altitude. It’s diameter and depth were 1m respectively and the heat exchanger was installed in the chamber. The temperature and pressure of the thermal vacuum chamber were measured by 9 temperature and 7 pressure sensors.