원판형 분자 드래그 펌프와 헬리컬 분자 드래그 펌프의 회전자에 대한 압력비교
김도행, 권명근, 황영규 · 대한기계학회 춘추학술대회 · 2008
Recently, Turbo-type molecular drag pumps (MDPs) are widely used in the liquid crystal display (LCD), semiconductor and other thin film industries. Molecular drag pumps are used as high-pressure stages in the hybrid-type turbomolecular pumps, where they can operate in the viscous, the transition and the free molecular flow regime. In this study is performed to investigate the pumping characteristics of disk-type molecular drag pump(DTMDP) and helical-type molecular drag pump(HTMDP) in the molecular transition flow region. The experiments are measured using five vacuum pressure gauges in the positions for rotors. The test is performed with nitrogen gas (N2). The present study is performed to investigate pumping characteristics of two pumps in the outlet pressure range from 0.4 to 533 ㎩.
Cited by 0 works.