고층 의료시설의 생물 오염물질 확산에 대한 연돌효과의 영향 분석

임태섭, 김병선 · 대한건축학회 논문집 - 계획계 · 2009

The purpose of this study is to analyze the effect of the stack pressure on the interior dispersion of airborne bio contaminants in the high-rise general hospital by conducting the field measurement and numerical analysis according to the outdoor temperature and the releasing vertical point of the tracer gas assumed as a viral contaminant. In the field measurement of the well-known high-rise hospital, the interior airflow was affected by the stack effect that appeared like high-rise buildings. The numerical simulation was verified by comparing its prediction result and the field measurement. In the numerical simulation, there is high possibility that the airborne bio contaminant emitted from the infected patient in the lower floors could be transported to the higher floors through the airflow driven by the stack effect. The concentration distribution of the tracer gas was mainly affected by the outdoor temperature and the vertical release point.