공회전 제한장치 차량용 축냉 열교환기의 성능에 대한 연구

이대웅, 권대복, 정석제 et al. · 한국자동차공학회 추계학술대회 및 전시회 · 2014

ISG system for the fuel economy and emission is very useful technology in the recent automobile industrial. However, when engine stop, air-conditioning system dont work due to compressor stop arise from passengers thermally dis-comfort. This study represented the cold storage system applied cold storage heat-exchanger integrated with evaporator. The experiments were conducted for optimum cold storage heat-exchanger design with different refrigerant flow pass, fin height and density, phase change materials in the heatexchanger. Also the cold storage release performance are examined effect on the ambient temperature and supplying air flow volume rate. The visualization of phase change material freezing and melting process inside cold storage heat-exchanger are conducted. The experimental results, air discharge temperature of cold storage system applied optimum cold storage heat-exchanger is 116 second delay to reach the 18°C set on the cabin comfort temperature range than current air-conditioning system. Finally, cold storage heat-exchanger integrated with evaporator is effective solution for ISG vehicles, to keep the thermal comfort in the cabin when short period of engine stop.

Cited by 0 works.