확관 응축부를 갖는 태양열 집열용 히트파이프 성능 비교 연구
정원복, 부준홍, 곽희열 · 한국태양에너지학회 학술대회논문집 · 2001
A special working condition of elevated condenser temperature may arise in such case as a solar collector for a medium temperature range. For this case, a heat pipe must be designed properly such that it may transfer a certain amount of heat to the abnormally hot condenser from the evaporator of which the relative temperature potential is not so high as in common applications. Among many wick structure candidates for this application, a slab wick was selected based on the promising performance data published previously. The thermal performance of heat pipes made of slab wick heat pipe, screen wick heat pipe and thermosyphon having enlarged condenser section were investigated for comparison. The heat pipes were made of 8.0 ㎜ dia.(evaporator section) and 25.4 ㎜ dia. (condenser section) copper tubes. The experimental data of these heat pipes were analysed and discussed in terms of thermal resistance against thermal load and coolant temperature.
Cited by 0 works.