한국형 발사체 연소기 연소시험설비 산화제 공급 시스템

서대반, 유병일, 정용갑 et al. · 한국추진공학회 학술대회논문집 · 2015

The combustion chamber test facility of 75-tonf class combustion chamber was constructed, then cold flow test of oxidizer supply system for its performance evaluation was conducted. In the 1st test leak tightness of the system under 100 bar condition was verified, and a flow rate and a filling time was measured as subline valve was opened. In the 2nd test, the maximum flow rate of liquid oxygen in the system was verified at the runtank pressure of 46 bar as main and subline valves was opened.