일정한 축하중과 반복 횡하중을 받는 외부 철골 보-기둥 접합부의 이력거동

양철민, 최경휴, 김영문 · 대한건축학회 학술발표대회 논문집 - 구조계 · 2005

Beam-to-column joints in steel frames are often subjected to a combination of bending moment transferred from beams and axial force from columns. Much research work of beam-to-column joints has been limited to the cases subjected to only bending moments. The objective of the present paper is to describe an experimental program carried out at the University of Chonbuk on three types of beam-to-column joints subjected to the combined action of cyclic bending moment and axial force. Test specimens possess three types of beam-to-column joint, namely, Double Web Angle(DWA2), Top and Seat angles with Double web angle(TSD2) and Fully Welded connection(FW2). The moment-rotation hysteresis loops and the failure modes for all the test cases are presented.

Cited by 0 works.