액체포집장치의 실험 장치 구성 및 기포점 측정

전상언, 박수형, 변영환 et al. · 한국추진공학회 학술대회논문집 · 2013

Liquid acquisition device in the liquid propellant supply system is required to protect entrance of gas bubble into the propulsion system. The device exploits the capillary effect of micro-sized poles in a screen and supplies pure liquid-phase propellant to the propulsion system. The bubble point is the most important performance parameter in the design of a liquid acquisition device. In this paper, measure the bubble point to configure the experiment for the bubble point measurement.

Cited by 0 works.

Authors