마이크로채널 열교환기 불균등 착상 특성
양영훈, 조금남, 임병한 · 대한설비공학회 2015년도 하계학술발표대회 · 2015
Present study investigated frost characteristics and thermal performance of micro-channel evaporator using R-410A under frosting condition. Local and average frost surface temperature, blockage ratio(BR), and heat transfer rate of the vertically installed micro-channel evaporator were measured under frosting condition. The evaporator consisted with four turns for 47 tubes. The test conditions were set at dry bulb air temperature of 2℃ and wet bulb air temperature of 1℃, air velocity of 1.5~2.5m/s, inlet quality of refrigerant of 0.2, mass flow rate of R-410A of 0.354~0.919kg/s, and inlet refrigerant temperature of -2.5℃. Non-uniform of frosting over the evaporator surface were observed over the whole test range. Overall thermal performance of the evaporator was decreased up to 25% at 80 min after frosting test started. Thermal performance was dropped to 75% when the BR was increased to 0.65. Uneven frost patterns over the micro-channel evaporator affected on the decrease of overall thermal performance of the evaporator. It was severe on the fin surface near the exit of micro-channel evaporator with high quality of R-410A.
Cited by 0 works.