스크롤 압축기의 누설감소를 위한 고정부재 체결위치 해석

Hyun Jin Kim, 정도영, 김중현 et al. · 대한설비공학회 학술발표대회논문집 · 1994

This study presents a way of improving the stability of the fixed scroll in scroll compressors. For the scroll compressor whose fixed scroll is designed to move in the axial direction for the axial compliance. the fixed scroll is under the influence of the over-turning moment produced by internal gas forces. Unless the over-turning moment is properly compensated by the moments of reaction forces at the supports of the fixed scroll, the fixed scroll would exhibit wobbling motion, increasing gas leakage through the gap between the orbiting and the fixed scrolls. The conditions on which the wobbling motion can be suppressed has been found analytically; The axial positioning of the fixed scroll holders should be made within a certain range. The center of the range is at the mid-height of the scroll wrap, and its margin depends on the magnitude of the internal gas forces and the radial distance from the scroll center to the wrap outer-end.

Cited by 0 works.

Authors