Исследование микробиоты воздуха в многопрофильном стационаре Санкт-Петербурга
Пунченко Ольга Евгеньевна, Косякова Карина Георгиевна, Н В Васильева · CyberLeninK (CyberLeninka) · 2014
Microbiological tests of air in hospitals are the very important constituent element in prophylaxis of health careassociated infections. The aim of the study is to assess air in hospitals accordingly to the microbiological standards. The results were analyzed for 1993-2011. There were 0,2 4,2% of the samples that did not meet the standard. The maximum amount of microorganisms was found while SanPiN 2.1.3.1375-03 was effective within validity period. SanPiN 2.1.3.2630-10 didn t normalize fungus, resulting in the minimal amount of mold. The frequency of sampling did not affect the result. Discussion Moulds are the causative agents of invasive fungal infections. Fungi can cause nosocomial infections. There is description of method to isolate fungi in the guidelines for control MUK 4.2.2942-11. Conclusion It is necessary to use a new procedure when assessing the air in hospitals.
Cited by 0 works.