화포 약실 내 차압 감소를 위한 점화제 주입 연구

장진성, 성형건, 유승영 et al. · 한국추진공학회 학술대회논문집 · 2011

Study on differential pressure in the chamber of cannon by adjusting the mass flow of ignition-gas has been conducted using the 1-D interior ballistics numerical code called IBcode. In case of large-caliber cannon, high temperature ignition-gas is injected to the chamber through the side hole of the primer to ignite the propellant. Therefore, mass flow of injected ignition-gas affects the propellant combustion in the chamber. Mass flow of each side hole of the current primer was uniformly distributed. In this study, differences of propellant combustion with different mass flow of each side hole have been imposed. Results in case of the mass flow increase in the direction to the base show that the differential pressure decreases compared to the uniformed mass flow.