차량용 스택 고출력 내구성능

김영민, 이종현, 윤종진 et al. · 한국신재생에너지학회 학술대회논문집 · 2007

The durability of 80 kW class stack module was tested in hydrogen recirculation and non-recirculation systems with the condition of 300Amps (constant current mode) and hydrogen pulse purging (10 seconds close/0.8 seconds open). A localized membrane failure in the interfacial area between membrane and sub-gasket, carbon corrosion in cathode electrode, and Pt dissolution/extraction have been found through the post mortem analysis such as CV, Impedance, SEM, and so on. The main reason of these mechanisms will be discussed in this study.

Cited by 0 works.

Authors