The wettability of liquid desiccant along the vertical surface of a plate type heat exchanger has been investigated. Liquid desiccant was supplied on the top of plate heat exchangers which have different groove gaps. Epoxy resin coating was sellected to improve the durability of the hydrophilic coating. Drying temperature and drying time were optimized to improve hydrophilic performance. Through visualization test, it is found that plate heat exchanger of 1.0 mm groove gap shows the largest wettability. As mass flow rate of supplied liquid desiccant increases, the wettability of liquid desiccant becomes enhanced.
Cited by 0 works.