유한요소법을 이용한 단일 분절 후방척추 유합술 시 준연성 고정술과 강성 고정술에 대한 비교

임상현, 강경탁, 전흥재 · 대한기계학회 춘추학술대회 · 2015

In this study, a finite element model of the human lumbar spinal segments (L2-L5) was developed to investigate the clinical effects of posterior dynamic stabilization (PDS) system such as the semi-flexible device and its influence on the mobility of adjacent intervertebral segments. Three models were developed and compared: (1) a lumbar spine with intact discs, a reference; (2) a one segment fusion vertically parallel paired semi-flexible fixator and total laminectomy and (3) a paired rigid fixator and total laminectomy implemented at levels L3-L4. The disc pressure (on the adjacent segments in the fused spine) increased compared with that of the intact spine, but the disc pressure of the semi-flexible spine was similar to that of the intact spine. The use of semi-flexible devices prepared closer results in comparison to that of the intact spine.