Анализ работы преобразователей напряжения повышающего типа с резонансным переключением при параллельном включении
Nikolay N. Goryashin, А. Н. Зорин, М. В. Лукьяненко et al. · CyberLeninK (CyberLeninka) · 2013
In the paper the problem of zero-current transition (ZCT) step-up boost converter parallel operating is considered. It is shown that high output resistance of the ZCT converter depends on resonant tank parameters and allows to iron out the input currents between converter cells without additional control loops. The criteria, which allow to define the range of input currents imbalance according to resonant tank parameters spread under ZCT converters parallel operating at output voltage regulation operation mode, are proposed. The criteria are based on sensitivity functions for each of resonant tank parameters and duty cycle of active switching transistor. To verify the theoretical analysis the paper presents P-spice simulation results of voltage regulator based on two step-up boost ZCT converters connected in parallel where resonant tank parameters spread between the corresponding elements.
Cited by 0 works.