절연구간 자동전원절체 통과시스템 보호계통 검토

홍현표, 이시빈, 김범곤 et al. · 한국철도학회 학술발표대회논문집 · 2010

The neutral section is the insulation device in electric railway catenary system. Electric train drives a neutral section in notch-off state. Automatic power changeover system is the technology to supply feeding power in neutral section of electric railway catanary system. Electric train drives it is notch-on state. Automatic power chageover switching is very short period time. Automatic power changeover device have to work perfect. A detecting technology location of train should be indext high-speed train. In addition, the power chageover device determines inrush current minimum point in electric train switching voltage state. Line-to-line short circuit fault and ground fault in power changeover equipment is required stability of power system and electric train system protection This paper is purpose of reviewing necessary power protection conditions and technical requirements to develop automatic power chageover system in neutral section.

Cited by 0 works.