The analysis of the remote power supply failures is carried out. It is established that the maximally high outlet temperature from the capacitor of power unit is the basic reason for the failures of mini TPS of gas transport system. The mathematical model of the heat-mass transfer processes while moving the working substance vapor through a cylindrical channel of condenser under intensive cooling of channel surface is developed. Is carried out the numerical simulation of nonstationary heat-mass transfer in the conditions of working medium condensation in the condenser. The influence of the ambient temperature and power output value of miniTES on the temperature of work substance at the output from the condenser is established. The values of the time to failure of typical remote power supplies of power supply under the climatic conditions of East Siberia and Far East of Russia are calculated. Are selected the directions of a possible increase in the indices of reliability miniTES, which work on the gas pipelines.