Сравнительная характеристика реагентных методов удаления токсичного шестивалентного хрома из электролитов ЭХРО

Н. А. Амирханова, В. В. Саяпова · Ecology and Industry of Russia · 2015

There were undertaking studies for selection of different chemical agents for hexavalent chromium removal from solutions. There was recommended chemical treatment with using of Na 2 SO 3  for spent electrolytes from electrochemical treatment of nickel-chromium alloys. For electrolytes with closed system is recommended use compound electrolytes with adding of barium salts in amount from o,5 to 3% depending on chromium quantity in alloy; in doing so improving output parameters of anode treatment and toxic hexavalent chromium removing.

Cited by 0 works. doi:10.18412/1816-0395-2013-5-42-43