Влияние исходных параметров электромеханического ремоделирования левого предсердия на эффективность радиочастотной аблации у пациентов с различными формами фибрилляции предсердий
Бокерия Лео Антонович, Филатов Андрей Геннадьевич, Ковалев Алексей Сергеевич · Анналы аритмологии · 2014
Objective is to analyze the initial electro-mechanical performance of the heart in order to identify patterns of success of radiofrequency ablation procedures in the late postoperative period. Materials and Methods: A clinical study was conducted between April 2009 and April 2014. The study involved 94 patients, including 49 men and 45 women with various forms of AF: 34 people with paroxysmal, 30 people with persistent and 30 people with long-lasting persistent form. The study was decided to analyze the entire pool of patients to identify mechanical (LA and LV dimensions) and electrophysiological (CFAE) patient characteristics, retaining sinus rhythm at the end of the study (finished observations 34 patients) and the manifestation of the ATachy (interrupted observation 60 patients), as well as the variability of signs electro-mechanical remodeling depending on the time when the first paroxysm was registered arrhythmias after surgery. Results: The upper limit of fragmentation duration in patients with freedom from AF (130 msec) lies less than a 95% lower limit of such patients with recurrent arrhythmias (140 msec). Spread between the medians of the total area of the fragmented areas was 15.4 cm2. There is a marked variation in the diameter and volume of the LA. The median of diameter of LA varies from 4.9 cm to 4.2 cm, respectively in reccurence and freedom from AF, the median volume of LA was 140 ml 91 mL, respectively. Other mechanistic characteristics, including the size of the LA, as previously described subordinate tendency to variability. Other primary obtained data, as well as basic electrophysiological parameters were not scanned because of apparent secondary or depending on the above characteristics. Conclusions: electroanatomical mapping technique should be used in patients with persistent AF, with a LA diameter of 4.5 cm and more, and volume more than 105-110 ml. Same critical values at which the application of interventional techniques does not give significant performance are LA diameter 5.5 cm, volume 200 ml and more, with duration and fragmentation of more than 190 msec and 30 cm2, respectively.
Cited by 0 works.
Authors
References
- HRS/EHRA/ECAS Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: Recommendations for Personnel, Policy, Procedures and Follow-Up
- The Registry of the German Competence NETwork on Atrial Fibrillation: patient characteristics and initial management
- Atrial Fibrillation Ablation Strategies for Paroxysmal Patients
- Challenges in the classification of atrial fibrillation
- Surgical treatment of atrial fibrillation.
- Initial Experience of Sequential Surgical Epicardial-Catheter Endocardial Ablation for Persistent and Long-Standing Persistent Atrial Fibrillation With Long-Term Follow-Up
- The techniques for catheter ablation of paroxysmal and persistent atrial fibrillation: a systematic review
- Surgical Ablation for Atrial Fibrillation in Cardiac Surgery a Consensus Statement of the International Society of Minimally Invasive Cardiothoracic Surgery (ISMICS) 2009
- Minimally invasive hybrid ablation procedure for the treatment of persistent atrial fibrillation: one year results.
- Atrial Fibrillation Therapy Now and in the Future