ПРОФИЛАКТИКА ПОВЫШЕНИЯ ВНУТРИБРЮШНОГО ДАВЛЕНИЯ КАК ЗНАЧИМЫЙ ФАКТОР УМЕНЬШЕНИЯ ИНТРАОПЕРАЦИОННОЙ КРОВОПОТЕРИ В ХИРУРГИИ СКОЛИОЗА
Новосибирский НИИ травматологии и ортопедии им. Я.Л. Цивьяна, М. Н. Лебедева, Анастасия Иванова et al. · Russian Journal of Spine Surgery (Khirurgiya Pozvonochnika) · 2014
Objective. Quantitative estimation of intraoperative blood loss volume in surgical correction of idiopathic scoliosis with patient’s positioning ensuring complete decompression of the anterior abdominal wall. Material and Methods. Results of surgical correction of idiopathic scoliosis in 122 patients who underwent surgery involving skeletal traction and posterior correction with hybrid instrumentation in the prone position were analyzed. Posterior correction in 60 patients from Group I was performed on a standard orthopedic table, and in 62 patients from Group II - on a modular operating table for spinal surgery providing complete decompression of the anterior abdominal wall. Results. The studied parameters in groups were as follows: deformity magnitude - 54.7° ± 16,3° in Group I vs 61.5° ± 19.4° in Group II, the length of the posterior spinal fusion - 12.5 ± 1.1 vs 12.8 ± 0.9 segments, the number of levels in transpedicular fixation - 4.1 ± 1.1 vs 4.2 ± 1.8, and surgery duration - 169.4 ± 30.3 min vs 159.0 ± 31.6 min, respectively. The volume of intraoperative blood loss showed significant difference between groups: 1024.9 ± 409.2 ml (28.6 ± 12.3 % of circulating blood) in Group I, and 595.2 ± 208.6 ml (16.7 ± 6.2 % of circulating blood) in Group II. Conclusion. Complete decompression of the anterior abdominal wall during surgical correction of idiopathic scoliosis allowed reducing intraoperative blood loss by 41.6 % and ensuring the absence of indications for blood transfusion in 48.4 % of operated patients. Hir. Pozvonoc. 2014; (1): 94-99.
Cited by 2 works. doi:10.14531/ss2014.1.94-99 Open-access PDF
Authors
References
- THE EFFECT OF INCREASED INTRA-ABDOMINAL PRESSURE ON RENAL FUNCTION IN MAN 1
- Intra-abdominal pressure measurement using a modified nasogastric tube: Description and validation of a new technique
- Estimation of blood loss after cesarean section and vaginal delivery has low validity with a tendency to exaggeration
- The Accuracy of Blood Loss Estimation After Simulated Vaginal Delivery
- Bedside measurement of intra-abdominal pressure (IAP) via an indwelling naso-gastric tube: Clinical validation of the technique
- The Effect of Patient Positioning on Intraabdominal Pressure and Blood Loss in Spinal Surgery
- Efficacy of Intraoperative Cell Salvage Systems in Pediatric Idiopathic Scoliosis Patients Undergoing Posterior Spinal Fusion With Segmental Spinal Instrumentation
- Blood management in pediatric spinal deformity surgery: review of a 2‐year experience
- Prediction of Massive Blood Loss in Scoliosis Surgery From Preoperative Variables
- Are Antifibrinolytics Helpful in Decreasing Blood Loss and Transfusions During Spinal Fusion Surgery in Children With Cerebral Palsy Scoliosis?