자동차 에어컨 시스템의 연간 냉매 누설량 평가

최원영, 김만회, 신현동 et al. · 대한설비공학회 하계학술발표회 논문집 · 2007

HFC refrigerant R134a has been widely used as a refrigerant of a mobile air conditioner and household refrigerator. However, it is one of the greenhouse gases, hence the emission of refrigerant has to be controlled. The Korean automobile companies whose major profits are from the export must be ready to the regulation of refrigerant leakage of other countries. A two-floored test space on whose first floor a compressor is installed was set. The concentration of leaked refrigerant was measured. The test were performed for single and dual evaporator system. The leakage during operation was larger than stationary condition. The leakage from the compressor increased along with compressor speed, but the leakage from another parts appeared no distinct change. The leakage from dual evaporator system was more than 60% of single evaporation system because the number of fittings and joints of dual evaporator system is twice of single evaporator system.

Cited by 0 works.

Authors