Эндоваскулярная профилактика тромбоэмболии легочной артерии при высоких проксимальных тромбозах нижней полой вены и вариантах анатомии почечных вен
Капранов Сергей Анатольевич, Burov Vp, А. Я. Ольмезова · Annals of Surgery (Russia) · 2014
This paper analyzes the results of a comprehensive study of the structural and functional features of the VCI in 479 patients with acute venous thromboembolism who underwent urgent or delayed endovascular prevention of pulmonary embolism, which as the final step includes the implantation of removable models of cava filters (VCF). The combined use of the method of physical and mathematical modeling in conjunction with ultrasound has allowed to analyze the state of hemodynamics in proximal VCI thrombosis and development options of the renal veins. The impact of the Vena Cava Filter on regional hemodynamics in the VCI depended not only on the structural and anatomical changes that accompany these interventions, but also on the nature of the thrombotic lesions of the VCI and the design of the embolus catching device itself. Floating thrombus’ distribution on VCI causes an acceleration of linear blood flow in its infrarenal segment that becomes turbulent. Long designed cava filters couldn’t be used in all variants of the renal veins fall and high VCI thrombosis, therefore in these cases cava filters of the first choice are short ones.
Cited by 0 works.