난연합판 제조 및 성능 평가
서현정, 박정은, 손동원 · 대한건축학회 학술발표대회 논문집 · 2016
Plywood is widely useful wood-based materials for building. However, the researches of fire or flame retardance for plywoods are lacking yet. The aim of this paper is the development of fire retardant plywood and confirmation of fire retardancy for plywood. In the National Institute of Forest Science (NIFOS), it developed the fire retardant agent, and applied to the plywood. Also, we confirmed the performance of fire resistance of fire retardant plywood according to KS F ISO 5660-1. It was prepared by an impregnation method using vacuum (0.79kgf/cm2, 30 minutes) and pressure (13kgf/cm2, 1 hour) to treat pores wood veneers. Cone calorimeter test was carried out to determine the flammability according to KS F ISO 5660-1. The test results of fire retardant plywood satisfied the “Level-3” fire retardancy criteria.