국내 남부지역의 골재원 변화에 따른 보통콘크리트의 기초 및 강도특성

조만기, 송원루, 박용준 et al. · 한국건축시공학회 학술.기술논문발표회 논문집 · 2015

When using non KS aggregate muck pile in general, compared to when using KS aggregate, when obtaining an identical slump a high unit quantity of water was confirmed, and when designing the concrete mix the compressive strength of concrete decreased due to an increase in W/B. Therefore because the use of non KS aggregate decreases the liquidity, strength and durability etc. qualities of concrete from an overall performance point of view, there is a need for the used of KS aggregate and when using aggregate that does not adhere to KS standards, it is determined there is a need for appropriate concrete mix design and care.