마이크로 구조 표면에서의 비등 성능 향상에 관한 연구

노현우, 조항진, 유동인 et al. · 대한기계학회 춘추학술대회 · 2015

Pool boiling experiments were conducted on flat and structured SiO₂ surfaces to investigate the effects of surface structures on boiling performances. A micro-structured surface was prepared with the MEMS fabrication methodology, and has regularly distributed micro-scale pillar array. Critical heat flux was enhanced on micro-structured surface up to ~1.7 ㎿/㎡, compared to flat surface with ~0.8 ㎿/㎡. Heat transfer coefficient of the micro-structured surface was higher than that of flat one at high heat flux region, and the difference became larger as applied heat flux increased. Droplet and bubble dynamics were studied and the results presented pinning behavior of liquid film and smaller bubble departure diameters on the micro-structured surface. At high heat flux region, liquid path was observed only on micro-structured surface, which guarantees consistent liquid supply rate to the heating surface.