붕괴메커니즘에 따른 직렬연결형 에너지 흡수장치를 가지는 내진골조의 응답특성

박해용, 오상훈 · 대한건축학회 학술발표대회 논문집 · 2016

This study targeted the seismic system with serial type energy absorbtion device consisting of a bolt joint between the beam end and a flange of column. On the characteristics of the system, the damper is included in the beam system. If the damper is designed properly, damage caused to the frame is concentrated in the damper which is located in beam end, and It can exhibit a response similar to the weak-beam mechanism. However, It is expected response characteristics are different according to strength relationships with column and beam member, related study also deficiencies in actuality. Therefore, in this study, it was carried out non-linear time history analysis for low-rise frame in which the seismic system has been applied. Analysis variables were set beam/column strength ratio. Analysis results, the case of weak-beam mechanism frame applied the target system, it exhibited superior seismic performance. And it was confirmed that it is possible to realize by weak-beam mechanism through the application of the system in the frame that is designed in a slightly weak-column mechanism.

Cited by 0 works.

Authors