열교환식 제습기를 적용한 액체 제습 시스템의 성능 실험에 관한 연구
고지운, 전동순, 문지현 et al. · 대한기계학회 춘추학술대회 · 2015
In this paper, performance experiments of the liquid desiccant system using LiCl aqueous solution with internally-cooled heat exchanger type dehumidifier were carried out. Effects of the flow rate and the relative humidity of the air on the dehumidification rate and the performance of the desiccant system were investigated. It was found that the relative humidity of the air had a great effect on the dehumidification rate. Dehumidification rate ranges about 106.1 ~ 242.6 g/min, and the COP for the liquid desiccant system ranges about 0.29 ~ 0.59 when the flow rate and the relative humidity of the air were in the range of 15 ~ 35 CMM and 40 ~ 80%.
Cited by 0 works.