고압 연소기 시험설비의 공기공급배관 기본 유동 해석

유이상, 이장환, 임지녕 et al. · 한국추진공학회 학술대회논문집 · 2015

This study was performed for modeling and simulation of pipe flux using an analysis program AMESim in order to analyze pipe flux of a high pressure combustor test facility operated under high temperature, high pressure and high mass flow rate. After the simulation, the correctness of facility composition was decided for analyzed pressure characteristic of high pressure combustor test facility under the maximum load required condition. Also, the study was applied for changing and modifying the test facility construction based on analysis result of checked pressure at the combustor inlet.

Cited by 0 works.