보행 중 하지 피부의 움직임 연구

구영준, 구승범 · 대한기계학회 춘추학술대회 · 2015

Accurate measurement of joint kinematics play an important role in understanding joint disease and assessing musculoskeletal disorders. Motion capture system was widely used to quantify joint kinematics. However, joint kinematics acquired by motion capture system was affected by soft tissue artefacts such as skin movements. To quantify accurate joint kinematics, we include the skin movements to analyze. Previous studies have used intrusive methods such as bone-pins or external fixators to quantify skin movements. These devices could be affected by gait environments and change gait motion. In this study we used a Bi-Plane Fluoroscopic (BPF) system and a motion capture system to quantify skin movements without bone-pins or external fixators. Seven healthy young males participated in this study. Multiple reflective markers were attached on both thigh and shank during treadmill walking at 0.9 ㎧, 1.2 ㎧ and 1.5 ㎧. Skin movements were calculated from BPF system and motion capture system by Anterior-Posterior (AP), Superior-Inferior (SI) and Medial-Lateral (ML) direction. Skin movements of thigh were larger than shank. Skin movements were largest at top of thigh. Skin movements in AP direction were larger than other directions. This study successfully quantified the kinematics with skin movements.